How the wipes are made
High-Pressure hydroentanglement is a process invented.

When using dust-free wipes, the wipe material itself may create polluting particles
(These pollutants are almost invisible)

Dust particles created by the material itself

Ions

Fibers

Crystals

Foreign pollutants on the material
Sontara® MicroPure Cleanroom Wipes can minimize these pollutants
Sontara® MicroPure Cleanroom Wipes has excellent dry wiping and dust picking performance (because wiping dry = wiping clean)
Excellent moisture absorption
Sontara® MicroPure Cleanroom Wipes itself is made of high liquid absorption material.

Sontara®
MicroPure Wipes
Double knit edge banding
polyester cleaning wipes
Tested according to IES RP CC 004.2

Low Content Ions and Extractables
Main feature - Low content ions and extractables

Use Sontara® MicroPure Cleanroom Wipes with the correct methods to achieve the best cleaning results.

Main features:
Exceptionally clean wiper fabric with extremely low particle generation,low extractables and ion levels.
More absorbent than 100% polyester.
Excellent wet and dry strength;solvent resistance.
Extremely soft wiper fabric.
Ingredients:Special blend of polyester and lyocell
Weight:68g / m2 。
Application:
Class 10 (M2.5) or higher level cleanroom.
Wiping delicate surfaces.
Packaging sensitive components.
Cleaning work surfaces.
General Cleanroom maintenanc.
.
Size and Packaging:9 "x 9 " (22.9 x 22.9 cm) - 150pcs / pack - 12 packs / box
Recommended models (Applicable to all MicroPure wipes)
* Based on the risk of pollution on the cleaning surface resulted from the manufacturing process.
Risk evaluation based on: the distance from the production line, the airflow position, the production line sensitivity, existence of other pollution sources etc.
請左右滑動表格,可查看更多欄位。
Scratch sensitivity of the surface |
Boundless, smooth surfaces |
Bounded, smooth surfaces |
Boundless, rough surfaces |
Bounded, rough surfaces |
---|---|---|---|---|
Low | Micropure AP or SL | Micropure AP or SL | Micropure AP or SL | Micropure AP |
Medium | Micropure 100 | Micropure 100 | Micropure 100 | Micropure 100 |
High | Micropure LP | Micropure LP | Micropure LP | Micropure LP |
請左右滑動表格,可查看更多欄位。
Comparison of Sontara® MicroPure Cleanroom Wipes with similar products on the market
Thickness | Roughness | Cleanliness | Absorption rate |
Absorption capacity |
Deforms after absorption |
Price | Particle generation |
|
Sontara® | Thick | Fine | High | Fast | High | No | Cheap | Low |
Similar products | Thin | Coarse | Low | Slow | Low | Yes | Expensive | High |
請左右滑動表格,可查看更多欄位。
Sontara® property sheet
Property | Sontara® MP SL |
Sontara® MP AP |
Sontara® MP 100 |
Sontara® MP LP |
Test Method |
---|---|---|---|---|---|
Composition | Lyocell | Woodpulp/ polyester |
Woodpulp/ polyester |
Lyocell/ polyester |
|
Basis weight oz/yd2(g/m2) | 1.5 (51) | 2.0(68) | 1.65(56) | 2.0(68) | ASTM D1117 Sec 17 |
Sheet Grab Tensile | |||||
MD lbs (N) | 21.4 (95) | 35.0(165) | 31.0(138) | 46.5(207) | ASTM D1117 Sec 7 |
XD lbs (N) | 15.1 (67) | 20.0(89) | 15.0(67) | 30.3(135) | ASTM D1117 Sec 7 |
Absorption Capacity | |||||
Intrinsic Ai mL/g | 8.20 | 4.27 | 4.76 | 6.85 | ASTM D6651-01 |
Extrinsic Ae mL/m2 | 418 | 276 | 267 | 465 | ASTM D6651-01 |
Absorption Rate | |||||
Intrinsic Ri mL/g/s | 150 | 34.0 | 38.0 | 27.1 | ASTM D6651-01 |
Extrinsic Re mL/m2/s | 7680 | 1755 | 2100 | 1833 | ASTM D6651-01 |
Particles | |||||
Po MM/m2 | 5.80 | 12.1 | 9.2 | 2.5 | IES-RP-CC004.2 |
BAS MM/m2 | 22.7 | 80.0 | 46.0 | 8.3 | IES-RP-CC004.2 |
Gelbo 1000/ft3 | 45.2 | 1.6 | 1.1 | INDA IST160. 1-92 | |
Extractables | |||||
Water,H2O % | 0.23 | 0.10 | 0.05 | 0.05 | IES-RP-CC004.2 |
Ispropyl Alcohol,IPA % | 0.02 | 0.03 | 0.03 | 0.04 | IES-RP-CC004.2 |
Ions | |||||
Na ppm | 22 | 18 | 13 | 5 | IES-RP-CC004.2 |
Fe ppm | 0 | 2 | 2 | 2 | IES-RP-CC004.2 |
Mg ppm | 50 | 69 | 45 | 29 | IES-RP-CC004.2 |
K ppm | 11 | 9 | 8 | 4 | IES-RP-CC004.2 |
Ca ppm | 356 | 333 | 313 | 231 | IES-RP-CC004.2 |
Fiber loss pcs(≧50μm)/ppm/m2 |
0.22 | 0.65 | 0.56 | 0.12 | ASTM D6652-01 |
Above data are for reference only. If the latest test information is needed, please contact our sales.